Alimentation de secours UPS 40kva triphasé 220v
- MAXI
- GUANGDONG
- ≤100 unités 25 jours
- 200 unités par mois
Caractéristique MXD31 40KVA :
1. Adoptez la dernière technologie d'onduleur à trois niveaux
2. Système de contrôle numérique DSP avancé
3. Correction du facteur de puissance d'entrée active (PFC)
4. Plage de fréquence d'entrée très large
5. Facteur de puissance de sortie 0,8
6. Fonctionnalités d'extensibilité puissantes
1. High level battery reliability:
- Automatic battery test
- Battery care, Battery life span can be increased approximately by 20% more
2. Back feed protection: to avoid energy feeding back into the mains supply
3. Bypass may be deactivated to allow operation as a frequency converter (at 50 or 60 Hz), or as stabilizer
4. Easy to maintain (front access)
5. Reliable, filtered, stabilised and regulated sine wave output (double on-line concersion technology VFI according to EN50091-3 specifications) with filters for atmospheric disturbance suppression
6. High reliability: IGBT technology, full microprocessor control with no-break static and manual bypass
7. High level diagnostics: event log with 128 messages, states, measurements and alarms-available from the built-in LCD in several languages
8. The UPS may be configured with the RS232 serial port (flash up-gradable )
MODEL | MXD 40K | |||
Input Mains | Rated voltage(V) | 380Vac 3phase+N | ||
Rated voltage&Range(v) | 380V±25% | |||
Frequency&Range(Hz) | 50/60Hz±4Hz | |||
Bypass Input | Rated voltage(V) | 220V/230V | ||
Rated voltage&Range(v) | 380V±25% | |||
Frequency&Range(Hz) | 50/60Hz±4Hz | |||
Output | Rated Power | 40KVA/32KW | ||
Rated Voltage(V) | 220V/230V | |||
Rated Voltage&Stability | 220V/230V±2% | |||
THDV | Linear Load | ≤3% | ||
Non-linear Load | ≤8% | |||
Output Power factor | 0.8 | |||
Tracking Frequency&Range(Hz) | 50/60Hz±4Hz | |||
Frequency&Stability (Battery Inverter) | (50/60+0.1)Hz | |||
Overload Capability | Less than 105%±5% for overload alarm;105%±5%~125%±5% for 2 minutes 125%±5%~150%±5% for 30 second; more than 150%±5% for 0.5 second | |||
Converting time (Normal Mode) | <1ms | |||
Converting time(ECO Mode) | <25ms | |||
System Efficiency(Linear Load) | ≥85 | |||
System Efficiency(ECO Mode) | ≥96% | |||
Physical | W*D*H (mm) | 455*830*1055 | ||
N.W. (kg) | 184 | |||
System | Display | LCD/LED | ||
EMS/EMI | Transmission | IEC 62040-02 | ||
Radiation | IEC 62040-02 | |||
Resisting Interference | IEC 61000-4-2.4.5 Level IV, IEC 61000-4-3 Level III | |||
Safety Requirements | GB4943-2001/IEC62040-1 | |||
Noise Level(1M) | ≤55dB | |||
Isolate Impedance(Ω) | ||||
Surge Current Protection | IEC60664-1 IV | |||
Environment | Operating Temperatures | 0℃~40℃ | ||
Elevation | <1000m | |||
Storing Temperatures | -15℃~45℃ | |||
Operation Humidity | 20%~95% | |||
Battery voltage | 384VDC |